Part Numbers
| Part Number | Ratio | Voltage Ratio |
|---|---|---|
| 3VTL460-120-120 | 1:1 | 120:120 |
| 3VTL460-208-120 | 1.73:1 | 208:120 |
| 3VTL460-240-120 | 2:1 | 240:120 |
| 3VTL460-277-120 | 2.30:1 | 277:120 |
| 3VTL460-288-120 | 2.4:1 | 288:120 |
| 3VTL460-346-120 | 2.88:1 | 346:120 |
| 3VTL460-380-120 | 3.16:1 | 380:120 |
| 3VTL460-380-380 | 1:1 | 380:380 |
| 3VTL460-400-120 | 3.33:1 | 400:120 |
| 3VTL460-416-120 | 3.46:1 | 416:120 |
| 3VTL460-480-120 | 4:1 | 480:120 |
| 3VTL460-480-208 | 2.30:1 | 480:208 |
| 3VTL460-480-277 | 1.73:1 | 480:277 |
| 3VTL460-480-480 | 1:1 | 480:480 |
| 3VTL460-575-120 | 4.79:1 | 575:120 |
| 3VTL460-600-120 | 5:1 | 600:120 |
| 3VTL460-600-240 | 2.5:1 | 600:240 |
| 3VTL460-120-480 | 0.25:1 | 120:480 |
| 3VTL460-197-480 | 0.41:1 | 197:480 |
| 3VTL460-189-480 | 0.39:1 | 189:480 |
| 3VTL460-178-480 | 0.37:1 | 178:480 |
| 3VTN460-069-120 | 0.57:1 | 69:120 |
| 3VTN460-069-120F | 0.57:1 | 69:120F |
| 3VTN460-069-120FF | 0.57:1 | 69:120FF |
| 3VTN460-120-120 | 1:1 | 120:120 |
| 3VTN460-120-120F | 1:1 | 120:120F |
| 3VTN460-120-120FF | 1:1 | 120:120FF |
| 3VTN460-240-120 | 2:1 | 240:120 |
| 3VTN460-240-120F | 2:1 | 240:120F |
| 3VTN460-240-120FF | 2:1 | 240:120FF |
| 3VTN460-277-120 | 2.31:1 | 277:120 |
| 3VTN460-277-120F | 2.31:1 | 277:120F |
| 3VTN460-277-120FF | 2.31:1 | 277:120FF |
| 3VTN460-300-120 | 2.5:1 | 300:120 |
| 3VTN460-300-120F | 2.5:1 | 300:120F |
| 3VTN460-300-120FF | 2.5:1 | 300:120FF |
| 3VTN460-346-120 | 2.88:1 | 346:120 |
| 3VTN460-346-120F | 2.88:1 | 346:120F |
| 3VTN460-346-120FF | 2.88:1 | 346:120FF |
| 3VTN460-480-120 | 4:1 | 480:120 |
| 3VTN460-480-120F | 4:1 | 480:120F |
| 3VTN460-480-120FF | 4:1 | 480:120FF |
Potential Transformer Model 3VTL460 3 Phase
Potential Transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. Designed for line to line operation but may also be used in a line to neutral or line to ground configuration at 58% of rated voltage. All transformers with rated voltages 346V and below are ANSI C57.13 Group 1. All transformers rated 480V and 600V are Group 2. The assembly consists of three separate transformers with all terminals accessible.
| Frequency | 50/60 Hz |
|---|---|
| Secondary Voltage | 120 VAC (Line-to-Line) |
| Insulation Level | 600V, 10kV BIL Full Wave |
| Accuracy Class (60Hz) | 0.6W, 1.2X per phase |
| Accuracy Class (50Hz) | 0.5 @ 10VA, 1.0 @ 20VA per phase |
| Thermal Rating (60Hz) | 150 VA @ 30°C, 100 VA @ 55°C |
| Thermal Rating (50Hz) | 125 VA @ 30°C, 75 VA @ 55°C |
| Standards | ANSI C57.13 |
- Assembly consists of three separate transformers with all terminals accessible.
- Terminals are No. 8-32 screws into ½" deep brass inserts with lock washer and flat washers.
- 480V and 600V rated units are ANSI C57.13 Group 2; all others are Group 1.